Views: 0 Author: Site Editor Publish Time: 2025-07-28 Origin: Site
Decrease in Filtrate Flow Rate Cause: Filter membrane clogging or wrinkling.
Impact: Reduced filtration efficiency.
Solution: Replace with a new bag and check whether the filtration system is unobstructed.
Filtrate Leakage Cause: Poor sealing at the bag edge or damage to the bag body.
Impact: Resulting in liquid contamination and loss.
Solution: Check whether the bag seal is intact and replace with a new bag.
Filtrate Contamination Cause: Poor quality of the filter membrane and uneven pore size.
Impact: Filtrate quality fails to meet standards.
Solution: Select high-quality filter membranes and replace with new bags.
Incomplete Filtration Cause: Insufficient filtration precision and excessively large pore size.
Impact: Substances in the filtrate are not completely removed.
Solution: Select filter bags with more precise pore sizes.
Shortened Service Life Cause: Severe filtration conditions exceeding the bearing range.
Impact: Frequent replacement increases usage costs.
Solution: Choose filter bags suitable for the process conditions.